Technoton DUT-E ATS-1 Automatic Tank Calibration Station

DUT-E ATS-1 Tank Calibration Station is made for automatic calibration of fuel tanks of vehicles as well as stationary fuel tanks/cisterns up to 3,000 liters, where fuel level sensor is installed. The station is controlled via Bluetooth from Android-based smartphone or tablet.

Description

DUT-E ATS-1 Tank Calibration Station is made for automatic calibration of fuel tanks of vehicles as well as stationary fuel tanks/cisterns up to 3,000 liters, where fuel level sensor is installed. The station is controlled via Bluetooth from Android-based smartphone or tablet. Automatic calibration station speeds up fuel tank calibration process by 2-3 times and provides higher accuracy of fuel tank calibration.

DUT-E ATS-1 automatic tank calibration station increases labor productivity of technicians and overall accuracy of fuel monitoring system.

Brand

Technoton

Technoton

Technoton was established in April 2000, at the early stage of emerging market of automotive telematics and GPS tracking systems. We started with development and manufacture of GPS tracking devices, fuel level sensors and fuel flow meters. Soon we focused on solving tasks of fuel consumption measurement and fuel usage monitoring, safe CANbus data reading and analysis.

Technoton’s technical team includes highly-qualified engineers and developers, who have wide expertise in micro controller units, mechanical engineering, computer science, programming and diagnosis.

Features

  • Continuous filling of liquid provides higher accuracy of fuel tank calibration;
  • Automatic shut-off in case pressure/temperature limits are surpassed.
  • Quick coupling hoses fittings – camlock;
  • Two operation modes – automatic and semi-automatic;
  • 2-3 times quicker calibration of fuel tank;
  • Human reliability” does not affect accuracy of calibration;

Applications

  • International transport
  • Agricultural machinery
  • Railway transport
  • Road construction machinery
  • Public transport

Specifications

  • Rated pumping speed, l/h : 1500
  • Relative calibration error (of tank volume), %, not more than : 0,5
  • Operation modes : automatic and semi-automatic
  • Nominal supply voltage, V : 12±3 V
  • Maximum current consumption, A, not more than : 30
  • Overall dimensions, mm : 700х335х335 mm
  • Weight, kg : 25±2
  • Interface for communication with Android device : Bluetooth 4.1
  • Time of uninterrupted operation, h, no more than : 2**

  For tanks of sophisticated shape the error value may reach ±1.0 %.

** With technological break for no less than 15 min long after each 2 hours of uninterrupted operation