Rheonik RHM015 Coriolis Mass Flow Meter

With highly accurate measurement performance and extreme capabilities, Rheonik meters are a natural choice for many applications and quickly provide payback through improved product quality and greatly reduced maintenance.

Description

With highly accurate measurement performance and extreme capabilities, Rheonik meters are a natural choice for many applications and quickly provide payback through improved product quality and greatly reduced maintenance. Whether used for transfer, batching, process feed or control, Rheonik meters can provide online flow and density measurement.

Brand

Rheonik

Rheonik

With highly accurate measurement performance and extreme capabilities, Rheonik meters are a natural choice for many applications and quickly provide payback through improved product quality and greatly reduced maintenance. Whether used for transfer, batching, process feed or control, Rheonik meters can provide online flow and density measurement.

Since our start in 1984 we are one of the innovation leading manufacturers worldwide of coriolis mass flowmeters in precision, function and design – and we want to deliver more.

Features

  • Typical measuring range up to 0.6 kg/min
  • Pressure ratings up to 1379 bar
    (20000 psi)
  • Temperature ratings from -196 to +210 °C
    (-321 to +410 °F) – extended on request
  • Mass flow uncertainty down to 0.05 %
  • Repeatability down to 0.05 %
  • 4 kHz measurement updates and response
    time of less than 1 ms when used with 40
    Series transmitters
  • Accurately measures flow rates
    down to 1 g/minThe Rheonik AnyPipeFit Commitment
    provides custom process connection type
    and size flexibility on any meter to suit
    your existing plant, saving time and
    expense on installation costs
  • Compact design with minimal footprint
  • Approved for use in hazardous areas
  • 304 Stainless steel enclosure, SS316
    optional
  • Integral and remote transmitter versions
    available

Applications

  • General Flow Control
  • Additive Dosing
  • Mixing and Batching
  • Chemical Injection
  • Package and Container Filling

Specification

  • Nominal Flow (Qnom)* 0.6 kg/min (1.32 lb/min)
  • Maximum Flow (Qmax)* 1.2 kg/min (2.65 lb/min)
  • Typical Minimum Flow (Qmin)* 0.002 kg/min (0.004 lb/min)
  • Serial Tube / Single Path Flow rates will be 50 % of the above listed parallel/dual path version
  • Operating Temperature Fluid temperature range options cover from -196 °C to +210 °C (-321 °F to +410 °F)
    For integral transmitter versions please refer to transmitter datasheet
  • Ambient Temperature -50 °C to +80 °C (-60 °F to +180 °F). High temperature version for oven installation up
    to +210 °C (+410 °F) available
  • Pressure Ratings Up to 1379 bar/20000 psi – dependent upon material
  • Electrical Connection Sensor
    w/o Integral Transmitter
    M20 x 1.5 standard cable entry for JM, SM terminal box versions
    Optional entries available : ½” NPT or M25 x 1.5 (only for SM) or ¾” NPT (only for SM)
    M16 x 1.5 standard cable entry for PM terminal box version
    Max. cable length to remote RHE transmitter 100 m/330 ft
  • Sensor Enclosure Materials Stainless steel 304 (standard), 316 (optional)
    Coated aluminum terminal box, 316 terminal box (optional)
  • Enclosure Type Protection class IP 66, NEMA 4 (standard), IP 66/67, NEMA 4X (optional)
  • Wetted Materials Flow tubes 316L, SuperDuplex, Sandvik HP160® or Alloy C22
    Manifolds 316L, seals FKM, FFKM, FVMQ
    Standard flanges 316Ti, other connections 316L
    Additional/customer specific materials available upon request
  • Process Connections Nearly any – the RHEONIK AnyPipeFit Commitment. Consult factory for types/sizes
    not listed in this data sheet on the Mechanical Construction pages
  • Pressure Rating Compliance PED 2014/68/EU Article 4, Section 3 (SEP)
  • Certifications and Approvals ATEX / IECEx Approvals zone 0, 1 (suitably rated RHE transmitter required), zone 2
    North American Approvals Cl. I, Div. 1, Gr. ABCD (suitably rated RHE required), zone 2
    American Bureau of Shipping (ABS) Product Type Approval for use on marine vessels
  • Testing and Inspection All sensors are hydro tested, calibrated and supplied with a traceable calibration
    certificate. Customized calibration and testing services are available
  • Project Documentation and
    QA, Services
    Rheonik offers a full set of services for large and complex engineering projects.
    Typical services offered are, but not limited to:
    • Certificates of origin and conformity, mill certificates
    • Data books including WPAR, WQS, NDT, test & quality plans, functional testing,
    calibration procedures, customized packing, factory acceptance etc.
    • Painting to project specification
    • Start up and commissioning services on/offshore
  • Options Special customized solution for machine integration
    Cleaning for oxygen service, …
    For more consult factory