Description
The flexible flow meter is designed to permit easy disassembly,cleaning, and reassembly. It is ideal for equipment that must be disassembled for maintenance. Users can change the flow meter tube only without changing the block.
The flexible flow meter is designed to permit easy disassembly,cleaning, and reassembly. It is ideal for equipment that must be disassembled for maintenance. Users can change the flow meter tube only without changing the block.
The flexible flow meter is designed to permit easy disassembly,cleaning, and reassembly. It is ideal for equipment that must be disassembled for maintenance. Users can change the flow meter tube only without changing the block.
The natural environment is preserved through the balance of solids, liquids and gases that exist on the earth. However, human civilization has caused pollution that has greatly damaged our environment. The task of the present generation is to restore our environment to its natural healthy state. And this is also the greatest challenge for 21st century science and technology.
KOFLOC’s corporate motto is “A Scientific Approach for Fluids.” In other words, we create products that scientifically measure and control the balance of liquids and gases. We trust that through our work we are making a contribution to the regeneration of the environment and to the establishment of a prosperous society.
Fluids | Air,N2,O2,H2,He,Ar,CO2 (Calibration with actual gas) For other gases, please consult us regarding conversion conditions or calibration with the actual gas to be used. |
|
Flow range (FS) | RK1100 | 10ML/MIN-20L/MIN |
RK1100PV | ||
RK1100V | 1L/MIN-20L/MIN | |
Accuracy | FS ±2% (Measurement point) * Option: FS ±1% (Measurement point) | |
Proof pressure | 0.5MPa | |
Available scale | 10:1 * Option 20:1 | |
Material | S | Al |
Body block | SUS303 · 304 | Al |
Tapered tube | Pyrex®, glass | |
Packing | FKM | NBR |
Float | Pyrex®, SUS316, glass | |
Protective cover | Acrylic resin | |
Heat resistance | MAX60℃ | |
Connection | Rc 1/4 (Standard), Rc 1/8 (Optional) |
Air (Flow rate under atmospheric pressure)
Max. flow rate | 10 | 20 | 30 | 50 | 100 | 150 | 200 | 300 | 500 | 1 | 2 | 3 | 5 | 10 | 15 | 20 |
Total length | ML/MIN | ML/MIN | ML/MIN | ML/MIN | ML/MIN | ML/MIN | ML/MIN | ML/MIN | ML/MIN | L/MIN | L/MIN | L/MIN | L/MIN | L/MIN | L/MIN | L/MIN |
120mm | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ |
150mm | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ |
200mm | - | - | - | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ |
250mm | - | - | - | - | - | - | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ |