Mass Flow Transmitter Rheonik RHE Flow Indicator
Inside the measuring sensor, there are precision tubes that are energized by an electromagnetic drive system, which itself is fed by the transmitter, to vibrate at their natural frequencies.When a liquid or gas flows through the vibrating tubes, it is subjected to additional deflection due to the degree of inertia that is generated. This deflection is recorded electronically by two velocity sensors and a high-precision electronic time delta. This measured quantity is proportional to the mass flow rate.
The RHE Coriolis Mass Flow transmitter has a 4 to 20 mA analog output with a programmable span, which is proportional either to the measured mass flow rate or the temperature; it also has an impulse output that supplies mass-proportional impulses.
Further conversion into physical units is done in a purely digital manner using a signal processor in the transmitter. At the same time, all of the appliance’s functions are constantly monitored. Should any disruptions occur, all of the errors that have occurred are immediately reported in the display?
All of the outputs and measuring functions can be verified at any time by the user by using the diagnostic mode in the appliance. The maintenance or new calibration intervals can be monitored via a run-time counter. For service or repair purposes, the transmitter and flow sensor can be replaced independently of each other.
This significantly reduces the costs of spare parts for the installed flow sensor/transmitter. During the factory calibration, the mass flow sensor can be calibrated independently of the transmitter.All sensor-specific calibration data can be programmed using magnetic switches located on the front panel. To achieve this, the instrument does not need to be opened.
All of the relevant data is buffered in a non-volatile semiconductor device (EEPROM).The RHEONIK mass flow meter consists of one of the RHM series flow sensors and one RHE series transmitter. The remote unit RHE 07/08 is for installation in a safe non-Ex area and is connected to the sensor via a single multi-conductor cable.
Please note, that the types RHE 07/08 and all sensor articles are available in non-Ex-versions (without Exnameplate). The RHE 11 (Ex d) may be installed and operated in hazardous Ex-areas (Zone 1 or 2). Ex-series sensors RHM (with Ex-Label) are when connected with an Ex- Transmitter, made for installation inside hazardous areas (Ex-zone 0, 1 or 2).The transmitter RHE includes seven printed boards that can be replaced during servicing. The remote electronic unit consists of two bent measuring loops in the shape of an omega.
Kind of Coriolis Flow Transmitter
The RHEONIK mass flow meter consists of one of the RHM series flow sensors and one RHE series transmitter. The remote unit RHE 07/08 is for installation in a safe non-Ex area and is connected to the sensor via a single multi-conductor cable. Please note, that the types RHE 07/08 and all sensor articles are available in non-Ex-versions (without Exnameplate). The RHE 11 (Ex d) may be installed and operated in hazardous Ex-areas (Zone 1 or 2).
Ex-series sensors RHM (with Ex-Label) are when connected with an Ex- Transmitter, made for installation inside hazardous areas (Ex-zone 0, 1 or 2). The transmitter RHE includes seven printed boards that can be replaced during servicing. The remote electronic unit consists of two bent measuring loops in the shape of an omega.
The RHEONIK mass flow meter consists of one of the RHM series flow sensors and one RHE series transmitter. The remote unit RHE 07/08 is for installation in a safe non-Ex area and is connected to the sensor via a single multi-conductor cable.
Please note, that the types RHE 07/08 and all sensor articles are available in non-Ex-versions (without Exnameplate).
-
RHE11 Rheonik Coriolis Flow Transmitter
The RHE 11 (Ex d) may be installed and operated in hazardous Ex-areas (Zone 1 or 2). Ex-series sensors RHM (with Ex-Label) are when connected with an Ex- Transmitter, made for installation inside hazardous areas (Ex-zone 0, 1 or 2). The transmitter RHE includes seven printed boards that can be replaced during servicing. The remote electronic unit consists of two bent measuring loops in the shape of an omega.
The RHE 12 transmitter is equipped with a 24 VDC mains supply. For trouble-free operation, the power supply must maintain the specified nominal voltage of +- 10%. When connecting the transmitters, always ensure that the power supply is switched off. The earthing for the power supply should be connected using the relevant RHE earthing.
-
RHE14 Rheonik Coriolis Flow Transmitter
The RHE14 is low cost, compact and ideal for OEM applications. I/O includes 4-20mA, pulse, flow direction, and RS232 serial data. Programming and configuration by SensCom™ software. The RHE06 is ATEX approved for hazardous area installation and offers pulse output and Error and Flow Direction. *The RHE06F+ has double pulse outputs with 90° phase shift for custody transfer applications
The RHE15 is an expansion module providing connectivity for an RHE14 transmitter to a PROFIBUS-DP system. The unit can optionally act as a gateway for other local instruments without PROFIBUS functionality.
- Rheonik Coriolis Flow TransmitterRHE16
- Rheonik Coriolis Flow TransmitterRHE21
- Rheonik Coriolis Flow TransmitterRHE26
- RHE 27 Rheonik Coriolis Flow Transmitter
- RHE 28Rheonik Coriolis Flow Transmitter
- RHE 45 Rheonik Coriolis Flow Transmitter
The types and capacities of the Coriolis Mass flow meters
- Small Size Coriolis Mass Flow Sensor
- Ideal for embedded systems and precise small flow applications
- Medium Size Coriolis Mass Flow Sensor
- Suited to industrial and process flow control and monitoring
- RHM 12 Mass Flow Meter flow rate
- RHM 15 Mass Flow Meter flow rate
- RHM 20 Mass Flow Meter flow rate
- RHM 30 Mass Flow Meter flow rate
- RHM 40 Mass Flow Meter flow rate
- Suited to industrial and process flow control and monitoring
- Large Size Coriolis Mass Flow Sensor
- Perfect for material movements in small and wide-scale operations
Contact us : sales@wmablog.com or visit to our E-Commerce
Other Articles
- Flow Meter Open Channel Untuk PLTU
- Instalasi Flow meter ultrasonic clamp on untuk air dingin mesin chiller
- Prosedur Instalasi Flow Meter Electromagnetic
- Meteran air Jenis flow meter Ultrasonic
- Flow meter ultrasonic clamp on untuk pipa HDPE
- Flow Meter Ultrasonic Jenis Clamp On Untuk Pipa PVC
- Harga Coriolis Mass Flow Meter
- Perlunya Resetting dan Kalibrasi Flow meter secara berkala
- Jenis Flow Meter Berdasarkan Prinsip Kerja dan Aplikasinya
- Penentuan Kapasitas Flow Meter Pada Aliran Air
- Flow Meter Ultrasonic Clamp on untuk Proses Destilasi Air Laut
- Flow Meter Ultrasonic Portable untuk Mengecek Sistem Pendingin Mesin
- Penggunaan Flowmeter Ultrasonic Pada Pengolahan air limbah