| Pipe Sizes | 2″, 3”, 4”, 6”, 8”, 10”, 12” |
| Flanges | 150 lb. ANSI Pattern |
| Pressure | 150 psi (10.3 bar) line pressure |
| Temperature | Operating | 10˚ to 140˚ F (-12˚ to 60˚ C) |
| Storage | -40˚ to 158˚ F (-40˚ to 70˚ C) |
| Accuracy | ±0.75% of reading on iMAG 4700p and 4700r (±1.0% iMAG 4700), ±0.025% of full-scale flow from low flow
cutoff to maxi. flow rate of 10 m/sec |
| Low Flow Cutoff | 0.5% of maximum flow rate |
| Material | Body (2”-12”) | Welded steel, epoxy-coated |
| Liner (2″ & 3”) | Polyurethane/Noryl® |
| Liner (4”-12”) | Santoprene flange/Polypropylene liner body |
| Electronics Housing | Powder-coated diecast aluminum |
| Electrodes | 316 stainless steel |
| Display | Type | 128×64 dot-matrix LCD |
| Digits | 5 Digit Rate | 8 Digit Total |
| Units Please Note:
All iMAG meters are factory
set for gallons per minute
(GPM) rate and gallons
total. If other units are
required, they can be set in
the field | Rate Volume Units | Rate Time Units | Total Volume Units |
Gallons
Liters
Barrels(42 gal)
Cubic Feet
Cubic Meters | Million Gallons²
Mega Liters²
Imperial Gallons
Million Imperial
Gallons² | Second
Minute
Hour
Day | Gallons
Liters
Barrels (42 gal)
Cubic Meters
Cubic Feet
Second Foot Day
Million Cubic Feet
Acre Feet
Acre Inches
Imperial Gallons
Fluid Ounces |
| Bidirectional¹ | Forward Total, Reverse Total, Net Total, Batch Forward Total, Batch Reverse Total (Batch totals can be reset) |
| Power | DC Power | 9-36 Vdc @ 250 mA max, 30 mA average |
Battery Backup
(Not for use as primary power) | DC powered units: Two lithium 3.6V ‘D’ batteries, replaceable.
AC powered units: One 9V alkaline battery, replaceable. |
AC Power (iMAG 4700r
and 4700p only) | 85-264Vac, 50/60Hz, 0.12A |
| Battery (iMAG 4700 only | One lithium 7.2V ‘D’ size battery pack, replaceable. |
Scaled Pulse
Output | Signal | Current sinking pulse, isolated, 36 Vdc at 10 mA max |
| Pulse Rates | User-scalable from 0.1 to 99,999.9 volume units/pulse. Pulse width is one-half of pulse period with minimum pulse width of 2.5 ms, 200 pulses/sec max. For battery option meters, pulse width varies with frequency, 150
pulses/sec max. |
| Options | 4-20mA Current Loop | Isolated, passive, 24Vdc, 650 Ω maximum current loop |
| HART/4-20mA | HART protocol over 4-20mA line |
High Speed Digital
Output (4700p only) | Isolated, open collector, 24 Vdc |
| Serial Communications | Isolated, asynchronous serial RS485 (Reconfigurable for RS232 or 3.3V CMOS), Modbus® RTU protocol (factory
selectable) |
| Cable | Power/Output Cable | 20ft (6m) standard length polyurethane jacketed cable—for power and outputs (lengths up to 200’ available). |
Remote Display Cable
(iMAG 4700r) | 20ft (6m) standard length polyurethane jacketed cable—for connection between meter and remote display (lengths up to 200’ available). |
| Conductivity | >20 microSiemens/cm |
| Empty Pipe Detection | Hardware/software, conductivity-based |
| Regulatory | #(EN 61326), 4”-12” certified to NSF/ANSI standard 61 60°C (140°F); 3” certified to NSF/ANSI standard 61
Cold Water 23°C (73.4°F) |
| Environmental | NEMA 6P, IP68 (10ft (3m) depth, continuously) |