CS Instruments Differential Pressure Robe For Testing Filter Performance

Differential pressure probe for testing filter performance. The small and easy-to-install differential pressure sensor allows you to test the filter performance of the compressed air system by measuring the differential pressure across the filter element (an indication of how much the filter element is soiled).

Description

Differential pressure probe for testing filter performance. The small and easy-to-install differential pressure sensor allows you to test the filter performance of the compressed air system by measuring the differential pressure across the filter element (an indication of how much the filter element is soiled). Thus it helps to maintain the required compressed air quality permanently. The sensor has a compact design with mounting bracket and sensor socket combined in one piece.

Brand

CS Instruments

CS Instruments

CS Instruments GmbH & Co. KG with locations in 24955 Harrislee and 78052 Villingen-Schwenningen/ Tannheim, is managed by Dipl. Eng. (FH) Wolfgang Blessing as sole Managing Director.

CS Instruments GmbH was established in the year 2002 by Christian Schuldt and Wolfgang Blessing as equal shareholders/Managing Directors.

Wolfgang Blessing already was sound a specialist on the sector of compressed air technology resp. industrial measurement technology long before the establishment of CS Instruments GmbH in the year 2002. Prior to the foundation of CS Instruments GmbH Dipl. Ing. (FH) Wolfgang Blessing acted for more than 10 years as primarily responsible product manager for industrial measurement technology at a worldwide known manufacturer of measuring instruments for compressed air and gases in the Black Forest. The technical knowledge and experience matched with the long-term practical knowledge was the corner stone for the success of CS Instruments.

Features

  • Minimizes pressure drops (loss in energy)
  • Allows exchange of filter elements according to the differential pressure specifications of the manufacturer (activated carbon filter excluded)
  • Ensures maximum performance of the filter elements and thus optimal compressed air quality level over time

Applications

  • for testing on compressed air systems

Specifications

  • Measuring range: 0 … 1.6 bar difference
  • Max. system pressure: 10 bar
  • Max. overload capability two-sided:
    15 bar
  • Max. one-sided overload capability:
    + side
    – side
    15 bar
    10 bar
  • Bursting pressure: 60 bar
  • Total error: 2.0% of the full scale
  • Output: 4 … 20 mA two-wire
  • Power supply: 10 … 30 V
    for output
    4…20 mA
  • Ambient operating
    temperature:
    -20 … +80 °C
  • Connections: 2× G 1/8″ female
    thread incl. plug-in
    coupling for 6 mm
    hose
  • Electrical connection: Round plug M12 × 1

Couldn’t find what you were looking for?

Contact us with your specification for assessment and availability of other products configurations.