Firetrol FTA990 Electric Fire Pump Controller

The Firetrol FTA990 Fire Pump Controller Disconnecting Device is an essential safety component designed to provide a UL Listed means of disconnecting and isolating the fire pump controller from the incoming power source. It ensures that maintenance and emergency isolation can be performed safely while adhering to strict industry standards.

Description

In mission-critical fire protection systems, the reliability of the power path is paramount. The Firetrol FTA990 serves as a robust disconnecting device that integrates seamless isolation capabilities with intelligent protection. Its primary function is to isolate the fire pump controller from the power grid, providing a secure breakpoint for service and safety.

This device is distinguished by its specialized overcurrent protection characteristics. Unlike standard circuit breakers that may trip prematurely during the high inrush currents typical of motor startups, the Firetrol FTA990 Fire Pump Controller is calibrated to accommodate these transients. It allows for the necessary power surges required to start the fire pump motor while still providing dependable protection against sustained overloads. The design features a non-adjustable circuit breaker, eliminating the risk of incorrect field settings and ensuring the device always operates within its safety design limits.

Brand

Firetrol

Firetrol

Firetrol, was founded in the early 1970’s and incorporated in Erie, Pennsylvania by an entrepreneur who saw an opportunity in a unique marketplace; the fire pump control industry. The business grew steadily between 1971 and 1980 as the company developed the first fire pump controller with molded case circuit breakers which drastically reduced their size, the first manual wound rotor controller for the New York City high-rise marketplace, the first medium voltage controller, and the first UL Listed controller with an automatic power transfer switch.

Specifications

  • Controller Type: Full Service Electric Fire Pump Controller
  • Standard Compliance: NFPA 20, UL218, FM1321/1323
  • Interface Model: Mark III+
  • Voltage Range: 200V to 600V (3-Phase)
  • Frequency: 50/60 Hz
  • Enclosure Rating: NEMA Type 2, 3R, 4, 4X, or 12
  • Pressure Rating: 0-300 psi (Standard)/ 0-500 psi (Optional)
  • Starting Method: Across the Line/ Part Winding/ Wye-Delta/ Autotransformer

Features

The following are included as standard with each controller:

  • Suitable for use as service equipment
  • NEMA Type 2 (IP22) Enclosure
  • Flange mounted disconnect handle lockable in the “ON” position

Applications

The FTA990 shall be specifically designed to assure complete upstream overcurrent protection coordination with the electric fire pump controller. A flange mounted disconnect handle lockable in the closed (ON) position shall be standard.