Brainchild Temperature Transmitter and Controller berbahan rendah mikroprosesor PID berbasis seri Fuzzy logic controller menggabungkan dua Layar LCD yang mudah dibaca yang menunjukkan nilai Proses (PV) dan Nilai set point (SP). Teknologi Fuzzy Logic yang tergabung dalam seri pengontrol ini memungkinkan proses untuk mencapai titik setel yang telah ditentukan dalam waktu singkat dengan minimum overshoot selama Start Up (Power ON) atau gangguan beban eksternal.
Type | Specification | |
C22 | DIN Size | 1/32 |
Dimensions (W* H* D) (mm) | 48* 24* 92 | |
Depth Behind Panel (mm) | 84 | |
Cut Out Dimensions (mm) | 45* 22.2 | |
Weight (gram) | 120 |
Type | Specification | |
C62 | DIN Size | 1/16 |
Mounting | Panel | |
Dimensions (W* H* D) (mm) | 48* 48* 59 | |
Depth Behind Panel (mm) | 50 | |
Cut Out Dimensions (mm) | 45* 45 | |
Weight (gram) | 160 |
Type | Specification | |
C82 | DIN Size | 1/8 |
Mounting | Panel | |
Dimensions (W* H* D) (mm) | 48* 96* 59 | |
Depth Behind Panel (mm) | 50 | |
Cut Out Dimensions (mm) | 45* 92 | |
Weight (gram) | 220 |
Type | Specification | |
C83 | DIN Size | 1/8 |
Mounting | Panel | |
Dimensions (W* H* D) (mm) | 96* 48* 59 | |
Depth Behind Panel (mm) | 84 | |
Cut Out Dimensions (mm) | 92*45 | |
Weight (gram) | 220 |
Type | Specification | |
C72 | DIN Size | 9/64 |
Mounting | Panel | |
Dimensions (W* H* D) (mm) | 72* 72* 59 | |
Depth Behind Panel (mm) | 50 | |
Cut Out Dimensions (mm) | 68*68 | |
Weight (gram) | 190 |
Type | Specification | |
C42 | DIN Size | 1/4 |
Mounting | Panel | |
Dimensions (W* H* D) (mm) | 96* 96* 59 | |
Depth Behind Panel (mm) | 50 | |
Cut Out Dimensions (mm) | 92*92 | |
Weight (gram) | 290 |
Type | Specification | |
R22 | DIN Size | – |
Mounting | DIN Rail | |
Dimensions (W* H* D) (mm) | 22.5* 96* 83 | |
Depth Behind Panel (mm) | – | |
Cut Out Dimensions (mm) | – | |
Weight (gram) | 160 |
Model | C22 | C62 | C82 | C83 | C72 | C42 | R22 |
---|---|---|---|---|---|---|---|
Power supply | 90 to 250 VAC, 47 –63 Hz ; 11 to 40 VDC / 20 to 28 VAC, 47– 63 Hz | ||||||
Power consumption | 8VA 4W Max | 10VA 5W Max | 12VA 6W Max | 8VA 4W Max |
Model | C22 | C62 | C82 | C83 | C72 | C42 | R22 |
Type | Thermocouple (J, K, T, E, B, R, S, N, L, U, P, C, D), RTD (PT100 (DIN), PT100 (JIS)), Current (mA), Voltage (Volts) | ||||||
Resolution | 18 Bit | ||||||
Sampling Rate | 5 Times / Second (200 msec) | ||||||
Maximum Rating | -2 VDC minimum, 12 VDC maximum | ||||||
Input Characteristics | Type | Range | Accuracy @ 25°C | Input Impedance | |||
J | -120 °C to 1,000.0 °C | ±2 ºC | 2.2 MΩ | ||||
K | -200 °C to 1,370.0 °C | ±2 ºC | 2.2 MΩ | ||||
T | -250 °C to 400.0 °C | ±2 ºC | 2.2 MΩ | ||||
E | -100 °C to 900.0 °C | ±2 ºC | 2.2 MΩ | ||||
B | 0 °C to 1,820.0 °C | ±2 ºC | 2.2 MΩ | ||||
R | -0 °C to 1,767.8 °C | ±2 ºC | 2.2 MΩ | ||||
S | -0 °C to 1,767.8 °C | ±2 ºC | 2.2 MΩ | ||||
N | -250 °C to 1,300.0 °C | ±2 ºC | 2.2 MΩ | ||||
L | -200 °C to 1900.0 °C | ±2 ºC | 2.2 MΩ | ||||
U | -200 °C to 600.0 °C | ±2 ºC | 2.2 MΩ | ||||
P | 0 °C to 1,395.0 °C | ±2 ºC | 2.2 MΩ | ||||
C | 0 °C to 2,300.0 °C | ±2 ºC | 2.2 MΩ | ||||
D | 0 °C to 2,300.0 °C | ±2 ºC | 2.2 MΩ | ||||
PT100(DIN) | -200 °C to 850.0 °C | ±0.4 ºC | 1.3 KΩ | ||||
PT100(JIS) | -200 °C to 600.0 °C | ±0.4 ºC | 1.3 KΩ | ||||
mA | -3 mA to 27 mA | ±0.05 % | 2.5 Ω | ||||
V | -1.3 VDC to 11.5 VDC | ±0.05 % | 1.5 MΩ | ||||
Temperature Effect | 1.5 μV / for all inputs except mA input, 3.0 μV / for mA | ||||||
Sensor Lead Resistance Effect | Thermocouple:0.2 μV / Ω:3- wire RTD:2.6 / Ω of Difference of Resistance of two leads:2- wire RTD:2.6 / Ω of Sum of Resistance of two leads | ||||||
Burn-out Current | 200nA | ||||||
Common Mode Rejection Ratio (CMRR) | 120 dB | ||||||
Normal Mode Rejection Ratio (NMRR) | 55 dB | ||||||
Sensor Break Detection | Sensor open for Thermocouple and RTD inputs, sensor short for RTD input, below 1 mA for 4 – 20 mA input, below 0.25 VDC for 1 – 5 VDC input, not available for other inputs | ||||||
Sensor Break Responding Time | Within 4 seconds for Thermocouple and RTD inputs, 0.1 seconds for 4 – 20 mA and 1 – 5 VDC inputs |
Model | C22 | C62 | C82 | C83 | C72 | C42 | R22 |
Type | Linear Current, Linear Voltage | ||||||
Range | -3 mA to 27 mA, -1.3 VDC to 11.5 VDC | ||||||
Accuracy | ± 0.05% | ||||||
Remote Set Point Option | Not Available | Available | Not Available | ||||
Input Impedance | Current : 2.5 Ω, Voltage : 1.5 MΩ | ||||||
Resolution | 18 Bits | ||||||
Sampling Rate | 1.66 Times / Second | ||||||
Maximum Rating | 280 mA maximum for Current Input, 12 VDC maximum for Voltage Input | ||||||
Temperature Effect | ±1.5 μV /°C for Voltage Input, ± 3.0 μV /°C for Current Input | ||||||
Sensor Break Detection | Below 1 mA for 4 – 20 mA input, below 0.25 VDC for 1 – 5 VDC input, not available for other inputs | ||||||
Sensor Break Responding Time | 0.1 second |
Model | C22 | C62 | C82 | C83 | C72 | C42 | R22 |
---|---|---|---|---|---|---|---|
Number of Event Input | 1 | 2 | 6 | 6 | 2 | 6 | 2 |
Logic Low | -10 VDC minimum, 0.8 VDC maximum | ||||||
Logic High | 2 VDC minimum, 10 VDC maximum | ||||||
Function | Refer to the user manual |
Model | C22 | C62 | C82 | C83 | C72 | C42 | R22 |
---|---|---|---|---|---|---|---|
CT Type | CT98-1 | ||||||
Accuracy | ± 5 % of Full-Scale Reading, ± 1 digit maximum | ||||||
Input Impedance | 294 Ω | ||||||
Measurement Range | 0 to 50 A-VAC | ||||||
Output of CT | 0 to 5 VDC | ||||||
Sampling Rate | 1 Time / Second |
Model | C22 | C62 | C82 | C83 | C72 | C42 | R22 |
---|---|---|---|---|---|---|---|
Type | Relay, Pulsed Voltage, Linear Voltage, and Linear Current | ||||||
Relay Rating | 2 A, 240 V AC, 200,000 Life Cycles for Resistive Load | ||||||
Pulsed Voltage | Source Voltage 5 VDC, Current Limiting Resistance 66 Ω | ||||||
Linear Output Resolution | 15 Bits | ||||||
Linear Output Regulation | 0.02 % for full load change | ||||||
Linear Output Settling Time | 0.1 Second (Stable to 99.9 %) | ||||||
Isolation Breakdown Voltage | 1,000 V AC | ||||||
Temperature Effect | ± 0.01% of Span /°C | ||||||
Load Capacity of Linear Output | Linear Current 500 Ω maximum, Linear Voltage10 KΩ minimum |
Model | C22 | C62 | C82 | C83 | C72 | C42 | R22 |
Maximum Rating | 2 A, 240 V AC, 200,000 Life Cycles for Resistive Load | ||||||
Alarm Function | Dwell Timer, Deviation Low, Deviation High, Deviation Band Low, Deviation Band High, Process High, Process Low, Range Low, Range High, Range High Low, Heater Break, Heater Short, Profile End, Profile Holdback | ||||||
Alarm Mode | Latching, Holding, Normal, Latching / Holding, Set Point Holding | ||||||
Dwell Timer | 0.1 to 4,553.6 Minutes |
Model | C22 | C62 | C82 | C83 | C72 | C42 | R22 |
---|---|---|---|---|---|---|---|
Interface | RS-485 | ||||||
Protocol | Modbus RTU (Slave Mode) | ||||||
Address | 1 to 247 | ||||||
Baud Rate | 2.8 KBPS to 115.2 KBPS | ||||||
Parity Bit | None, Even or Odd | ||||||
Stop Bit | 1 or 2 Bits | ||||||
Data Length | 7 or 8 Bits | ||||||
Communication Buffer | 160 Bytes |
Model | C22 | C62 | C82 | C83 | C72 | C42 | R22 |
---|---|---|---|---|---|---|---|
Output Signal | 4 – 20 mA, 0 – 20 mA, 0 – 10 VDC | ||||||
Resolution | 15 Bits | ||||||
Accuracy | ± 0.05 % of Span ± 0.0025% / °C | ||||||
Load Resistance | 0 to 500 Ω for Current Output, 10 KΩ minimum for Voltage Output | ||||||
Output Regulation | 0.01 % for full load change | ||||||
Output Setting Time | 0.1 Second (Stable to 99.9 %) | ||||||
Isolation Breakdown | 1,000 VAC minimum | ||||||
Integral Linearity Error | ±0.005 % of Span |
Model | C22 | C62 | C82 | C83 | C72 | C42 | R22 |
---|---|---|---|---|---|---|---|
Temperature Effect | ±0.0025 % of Span / °C | ||||||
Saturation Low | 0 mA or 0 VDC | ||||||
Saturation High | 22.2 mAor 5.55 VDC,11.1 VDC minimum | ||||||
Linear Output Range | 0 – 22.2mA (0 – 20mA / 4 – 20mA), 0 – 5.55VDC (0 – 5VDC / 1 – 5VDC), 0 – 11.1VDC (0 – 10VDC) |
Model | C22 | C62 | C82 | C83 | C72 | C42 | R22 |
---|---|---|---|---|---|---|---|
Keypad | 4 Keys | ||||||
Display Type | 4 Digit LCD Display | ||||||
Number of Display | 2 | 3 | 2 | ||||
Upper Display Size | 0.4” | 0.58” | 0.7” | 0.7” | 0.58” | 0.98” | 0.98” |
Lower Display Size | 0.19” | 0.3” | 0.4” | 0.4” | 0.32” | 0.55” | 0.25” |
Model | C22 | C62 | C82 | C83 | C72 | C42 | R22 |
---|---|---|---|---|---|---|---|
Interface | Micro USB | ||||||
PC Communication Function | Parameter Configuration and Firmware Upgrade |
Model | C22 | C62 | C82 | C83 | C72 | C42 | R22 |
---|---|---|---|---|---|---|---|
Output 1 | Reverse (Heating) or Direct (Cooling) Action | ||||||
Output 2 | PID cooling control, Cooling P band 50 ~ 300 % of PB, Dead band -36.0 ~ 36.0 % of PB | ||||||
ON-OFF | 0.1 °C~50.0 °C( 0.1~ 90.0 °F) hysteresis control (P band = 0) | ||||||
P or PD | 0 – 100.0 % off-set adjustment | ||||||
PID | Fuzzy logic modified Proportional band 0.1 °C~500.0°C (0.1~900.0 ), Integral time 0-3,600 Seconds, Derivative time 0-360.0 seconds | ||||||
Cycle Time | 0.1 to 90.0 Seconds | ||||||
Manual Control | Heat (MV1) and Cool (MV2) | ||||||
Auto-tuning | Cold Start and Warm Start | ||||||
Failure Mode | Auto transfer to manual mode while sensor breaks or A – D Converter damage | ||||||
Ramping Control | 0~500.0 °C (0~900.0°F )/Minute or 0~500.0 °C (0~900.0 °F )/ Hour Ramp Rate |
Model | C22 | C62 | C82 | C83 | C72 | C42 | R22 |
---|---|---|---|---|---|---|---|
Function | First Order | ||||||
Time Constant | 0, 0.2, 0.5, 1, 2, 5, 10, 20, 30, 60 Seconds Programmable |
Model | C22 | C62 | C82 | C83 | C72 | C42 | R22 |
---|---|---|---|---|---|---|---|
Availability | NO | NO | Option | NO | |||
No of Programs | N/A | N/A | 4/2/1 | N/A | |||
Number of Segments / Program | N/A | N/A | 4/8/16 | N/A |
Model | C22 | C62 | C82 | C83 | C72 | C42 | R22 |
---|---|---|---|---|---|---|---|
Operating Temperature | -10 °C to 50 °C | ||||||
Storage Temperature | -40 °C to 60 °C | ||||||
Humidity | 0 to 90 % RH (Non – Condensing) | ||||||
Altitude | 2,000 Meters maximum | ||||||
Pollution | Degree II | ||||||
Insulation Resistance | 20 MΩ minimum (@ 500 VDC) | ||||||
Dielectric Strength | 2,000 V AC, 50 / 60 Hz for 1 Minute | ||||||
Vibration Resistance | 10 to 55 Hz, 10 m / s2 for 2 Hours | ||||||
Shock Resistance | 200 m / s2 (20 g) | ||||||
Molding | Flame Retardant Polycarbonate |
Model | C22 | C62 | C82 | C83 | C72 | C42 | R22 |
---|---|---|---|---|---|---|---|
Safety | UL61010-1, CSA 22.2 No.61010-1-12, EN61010-1 (IEC1010-1), RoHS, REACH | ||||||
Protective Class | IP65 for panel (in the process), IP20 for terminals and housing, all indoor use | ||||||
EMC | EN61326 |
Sumber: brainchildtw.com | inaparts.com