Technoton DFM-D Differential Fuel Flow Meter

DFM D differential fuel flow meter is designed for diesel fuel consumption measurement in fuel lines of vehicles and stationary engines, and is used as part of GPS vehicle tracking system.

Description

DFM D differential fuel flow meter is designed for diesel fuel consumption measurement in fuel lines of vehicles and stationary engines, and is used as part of GPS vehicle tracking system. In addition, DFM D registers working time of engine in various modes of operation. DFM D is used for consumption monitoring of:

  • diesel fuel;
  • heating oil;
  • other types of liquid fuel with a kinematic viscosity of 1.5 to 6 mm2/ s.

DFM D fuel flow meters, which re equipped with display, are used as a stand-alone (autonomous) solution for accounting fuel consumption, not requiring any connection to a web-server. DFM D are more suitable for modern engines (Common rail or pump injector fuel systems) of vehicles and stationary units.

Brand

Technoton

Technoton

Technoton was established in April 2000, at the early stage of emerging market of automotive telematics and GPS tracking systems. We started with development and manufacture of GPS tracking devices, fuel level sensors and fuel flow meters. Soon we focused on solving tasks of fuel consumption measurement and fuel usage monitoring, safe CANbus data reading and analysis.

Technoton’s technical team includes highly-qualified engineers and developers, who have wide expertise in micro controller units, mechanical engineering, computer science, programming and diagnosis.

Features

  • Built-in battery
  • Differential measurement of fuel consumption
  • Replaceable mud filter

Applications

  • Bus
  • Truck
  • Marine Vessel
  • Minning Vehicles
  • Diesel Locomotives
  • Agricultural Machinery
  • Diesel General Engine
  • Road Building Machinery

Specifications

Connecting threadM14x1.5
Nominal pressure, bar2
MAX pressure, bar25
Supply voltage, V10-45
Overvoltage protection, V≤100
Current consumption, mA (24 V/12 V), mA25 / 50
Operating temperature, (without/with display), °C-40..+85/
-20..+60
Ingress Protection RatingIP54
Relative accuracy error per chamber, %, not more than1

Additional Informations

ModelChamber volume, mlMIN flow rate in each chamber, l/hMAX flow rate in each chamber, l/h
DFM 100D510100
DFM 250D12,550250
DFM 500D20100500

DFM modifications

Following DFM types are available:

  • fuel flow meters with display, one-chamber or differential);
  • fuel flow meters without display, one-chamber or differential).

DFM order identification codes* A symbol is not specified for differential fuel flow meters.

** For autonomous fuel flow meters Z version is not used.

*** This version is delivered upon special order. Designation U is available only for one-chamber flowmeters.

Output signals (specified in purchase order): pulse, digital RS232, digital RS485, digital CAN/S6

Couldn’t find what you were looking for?

Contact us with your specification for assessment and availability of other products configurations.

Click Here