Rheonik RHM15 Coriolis Mass Flow Meter

Rheonik meters are a highly accurate and versatile choice for various industrial applications, offering a quick return on investment through improved product quality and significantly reduced maintenance costs.

Description

With highly accurate measurement performance and extreme capabilities, Rheonik meters are a natural choice for many applications and quickly provide payback through improved product quality and greatly reduced maintenance. Whether used for transfer, batching, process feed or control, Rheonik meters can provide online flow and density measurement.

Brand

Rheonik

Rheonik

With highly accurate measurement performance and extreme capabilities, Rheonik meters are a natural choice for many applications and quickly provide payback through improved product quality and greatly reduced maintenance. Whether used for transfer, batching, process feed or control, Rheonik meters can provide online flow and density measurement.

Since our start in 1984 we are one of the innovation leading manufacturers worldwide of coriolis mass flowmeters in precision, function and design – and we want to deliver more.

Specifications

ParameterSpecification / Value
Nominal Flow (Qₙₒₘ)*180 kg/min (396.8 lb/min)
Maximum Flow (Qₘₐₓ)*240 kg/min (529.1 lb/min)
Typical Minimum Flow (Qₘᵢₙ)*0.5 kg/min (1.1 lb/min)
Operating TemperatureFluid temperature range options cover applications from -50°C to +210°C (-58°F to +410°F). For integral transmitter versions, please refer to the transmitter datasheet.
Ambient Temperature-50 °C to +80 °C (-60 °F to +180 °F). High temperature version for oven installation up to +210 °C (+410 °F) available.
Pressure RatingsUp to 400 bar / 5801 psi – dependent upon material.
Electrical Connection Sensor w/o Integral TransmitterM20 x 1.5 standard cable entry for JM, SM terminal box versions.

Optional entries available: ½” NPT or M25 x 1.5 (only for SM) or ¾” NPT (only for SM).

M16 x 1.5 standard cable entry for PM terminal box version.

Max. cable length to remote RHE transmitter 100 m/330 ft.

Sensor Enclosure MaterialsStainless steel 304 (standard), SS 316L (optional).

Coated aluminum terminal box, SS 316L terminal box (optional).

Enclosure TypeProtection class IP66 (IP66 is mostly equivalent to NEMA 4X).

Optionally IP66-IP67 (IP67 declared by manufacturer, IP67 is mostly equivalent to NEMA 6).

Wetted MaterialsFlow tubes SS 316Ti or SuperDuplex.

Manifolds SS 316L; seals: FKM, FFKM, FVMQ.

Standard flanges SS 316Ti, other connections SS 316L.

Additional/customer-specific materials available upon request.

Process ConnectionsThe Rheonik AnyPipeFit Commitment covers a wide range of process connections and types. Consult the factory for types/sizes not listed in this data sheet on the Mechanical Construction pages.
Pressure Rating CompliancePressure Equipment Directive (PED).
Certifications and ApprovalsATEX / IECEx Approvals for Zone 0, 1, 2 (details see page 13).

North American Approvals Cl. I, Div. 1, 2, Gr. A, B, C, D, Zone 0, 1, 2 (see page 13).

American Bureau of Shipping (ABS).

DNV approval for marine applications.

Testing and InspectionAll sensors are hydro tested, calibrated, and supplied with a traceable calibration certificate. Customized calibration and testing services are available.
Project Documentation and QA, Services12Rheonik offers a full set of services for large and complex engineering projects. Typical services offered are, but not limited to:34

• Certificates of origin and conformity, mill certificates56

• Data books including WPAR,7 WQS, NDT, test & quality plans, functional testing, calibration procedures, customized packing, factory acceptance, etc.

• Painting to project specification

• Start-up and commissioning services on/offshore

OptionsCustomization services for machine integration. Consult the factory.

* Qnom pressure drop across a parallel tube sensor will be approximately 1.4 bar (20.3 psi) for H2O. Sensors can be operated at higher flow rates up to Qmax, but the pressure drop will be higher. Typical Minimum Flow Qmin is the recommended lowest flow rate for an accurate measurement. Sensors will measure flow rates lower than Qmin, but uncertainty will increase beyond 1% ofthe  rate.

The flow rate specifications above relate to standard pressure, parallel tube, and manifold sensor versions. Models with higher pressure ratings have increased wall thickness and will have higher pressure drops.

Features

  • Typical measuring range up to 240 kg/min (529.1 lb/min)
  • Pressure ratings up to 400 bar (5801 psi)
  • Temperature ratings from -50 to +210 °C (-58 to +410 °F)
  • Mass flow uncertainty down to 0.05%
  • Repeatability down to 0.05 %
  • 4 kHz measurement updates and response time of less than 10 ms when used with RHE 40 Series transmitters
  • Accurately measure flow rates down to 0.5 kg/min
  • The Rheonik AnyPipeFit Commitment provides custom process connection type and size flexibility on any meter to suit your existing plant, saving time and expense on installation costs
  • Compact design with minimal pipeline footprint
  • Approved for use in hazardous areas
  • SS 304 Stainless Steel Enclosure, SS 316L optional
  • Integral and remote transmitter versions available

Applications

  • General Flow Control
  • Plant Balance
  • Additive Dosing
  • Mixing
  • Batching
  • Package and Container Filling

Downloads

Rheonik RHM15 Coriolis Mass Flowmeter