Rheonik RHE 14 DIN Rail Mount Flow Transmitter

With highly accurate measurement performance and extreme capabilities, Rheonik meters are a natural choice for many applications and quickly provide payback through improved product quality and greatly reduced maintenance.

Description

With highly accurate measurement performance and extreme capabilities, Rheonik meters are a natural choice for many applications and quickly provide payback through improved product quality and greatly reduced maintenance. Whether used for transfer, batching, process feed or control, Rheonik meters can provide online flow and density measurement.

Brand

Rheonik

Rheonik

With highly accurate measurement performance and extreme capabilities, Rheonik meters are a natural choice for many applications and quickly provide payback through improved product quality and greatly reduced maintenance. Whether used for transfer, batching, process feed or control, Rheonik meters can provide online flow and density measurement.

Since our start in 1984 we are one of the innovation leading manufacturers worldwide of coriolis mass flowmeters in precision, function and design – and we want to deliver more.

Features

• Low installation cost
• Space saving DIN rail mounting housing
• Analog output for mass flow
• Tandem pulse outputs – one passive open
collector, one active TTL
• 2 digital status outputs
• Digital input for external zero command
• Metric and English units
• Power consumption 2W
• RS232 communications port
• Dedicated SensCom software packages for
configuration and control

Applications

• Filling and dispensing
• Liquid and gas applications
• Feed stocks and transfers

Specifications

  • Housing: DIN rail mounting enclosure (polycarbonate (PC) and polyphenylene oxide (PPO))
  • Enclosure Rating: IP 20
  • Ambient Temperature: -40°C to +65°C (-40°F to +149°F)
  • Dimensions: 70 x 86 x 58 mm (2.76 x 3.39 x 2.28 in)
  • Operation: Via serial port using SensCom PC software
  • Sensor Cable Connection: Screw terminals
  • Analog Outputs: 1 active 4-20 mA output, configurable for mass flow or temperature
  • Pulse Outputs: 2 outputs, one active (TTL, IOHmax = -0.4 mA, IOLmax = 8 mA), one passive
    (opto-isolated open collector type, Fmax = 10 kHz, Umax = 24 V, Imax= 10mA
    (requires external power supply and site installed current limiting/pull up resistor)) operating in tandem
  • Digital Outputs: 2 digital outputs individually configurable as either active or passive (requires external power
    supply and site installed current limiting/pull up resistors) for error and flow direction
  • Digital Inputs: 1 input for remote zero
  • Power Supply: 8 – 28 VDC +/- 10%
  • Digital Data Communications: RS232 with either HART or Rheonik simple ASCII protocol
  • Weight: 0.2 kg (0.44 lb)