Jain Xonic 100LM Ultrasonic Open Channel Flow Meter

The Jain Xonic 100LM Ultrasonic Open Channel Flow Meter is a high-precision, non-contact measurement system designed for monitoring flow in flumes, weirs, and open channels.

Description

The Jain Xonic 100LM Ultrasonic Open Channel Flow Meter is engineered to handle the complexities of gravity-fed water systems. Traditional flow measurement in open channels can be difficult due to debris, turbulence, and corrosive liquids. The Xonic 100LM overcomes these challenges by using a non-contact ultrasonic sensor mounted above the water surface. This sensor measures the exact head (level) of the water, and the integrated flow computer instantly calculates the flow rate based on the specific geometry of the flume or weir in use.

Brand

Jain Technology

Jain Technology

Especially JAIN TECHNOLOGY makes fully digitalized various kind of ultrasonic flowmeters for liquid and gas. Also, JAIN TECHNOLOGY has CERTIFIED CALIBRATION LABORATORY for liquid flow in accordance with the recognized International Standard ISO/IEC 17025:2005.

JAIN TECHNOLOGY provides the total solutions of the ultrasonic flow measurements from planning and design, through to manufacturing, installation and commissioning. We deliver a complete range of flow measuring services, as well as specialized assistance in a range of ultrasonic flowmeters.

Specification

  • Principle: Anti-Round Mode, Transit-Time With Cross-Correlation, Fast Fourier Transform
  • Measuring Path: 2 or 4 path
  • Measuring Width: 20 meters
  • Accuracy: 1%
  • Sensitivity : 0.003 m/s
  • Data Output : 4-20mADC, Relay
    RS-232C / RS-485
  • Data Input : 4-20mADC
  • Datalogger: 4Mbytes
  • Display: Large Color LCD (128×64)
  • Temperature Range
    • Electronics : -20 to +60℃
    • Transducer: -40 to +120℃
  • Power: 110~220VAC, free voltage
  • Enclosure
    • Electronics: NEMA 4 (IP65)
    • Transducer: Submersible (IP68)

Feature

  • 2 to 4 path measurement
  • Cross flow installation
  • IP68 submersible transducers
  • Open Channel Flowmeter

Application

Xonic 100LM measure flow velocity directly with patented 4 path transducers. Transducers are located at the end of each side to prevent any obstructions, and level is located on the top of the open channel, and accuracy is within 2% of actual flow.

Cross Flow Installation

In case of winding open channel, Xonic 100LM can use Cross Flow Installation to keep better accuracy. Path 1 & 3, Path 2 & 4 can be installed as cross path to keep better accuracy.