Gastec S330 HYDROTEC

For measuring sulphides in waste water and sludge

This kit enables quick measurement (approx. 10 min.) of sulphide in bodies of water or in waste water without any special equipment and skills. Take a sample with the gas generator tube, add sulphuric acid and simply measure the amount of hydrogen sulphide generated using the detector tube.

Description

For measuring sulphides in waste water and sludge

This kit enables quick measurement (approx. 10 min.) of sulphide in bodies of water or in waste water without any special equipment and skills. Take a sample with the gas generator tube, add sulphuric acid and simply measure the amount of hydrogen sulphide generated using the detector tube.

Brand

Gastec

GASTEC

Although, technology is always evolving, one demand on our products never changes: the demand for customer safety. Whenever we contribute to customer safety, we are presented with an opportunity to develop further.

GASTEC holds this corporate creed of safety and development in high esteem, as it strives to grow while always putting customer safety first.

Features

  • This kit enables quick measurement (approx. 10 min.) of sulphide in bodies of water or in waste water without any special equipment and skills

Applications

  1. The measured out mud and soil is put in the generation tube and 5mL of distilled water are added. In case of muddy water, it suffices to add a small amount of distilled water (measured out in a graduated cylinder) to the gas generation tube. Put the cap on the generation tube.

2. Both ends of the detector tube (No.201H or No.201L) are broken off, and one end of the detector tube is connected to the gas generation tube and the other to the gas sampling pump.

3. 18N 2 mL of sulphuric acid are added to the gas generation tube.

4. Pull the handle of the gas sampling pump to draw in a sample of the generated hydrogen sulphide. (By repeating this process several times, all sulphides become hydrogen sulphide several times repeatedly). The scale in the detector tube is read, and the concentration of the sulphide in the sample is calculated.

Specifications

Substance to be measuredTube no. & nameMeasuring range
(ppm)
Scale range
(ppm)
No. of
tests
per box
Detector tube typeNotes
Sulphides201HSulphides0.02-0.20mg0.02-0.20mg10Sulphides measurement system No.330
201LSulphides0.002-0.020mg0.002-0.020mg10Sulphides measurement system No.330