Description
Gas mixer [CUBEGM-Xα series] is a model in which a buffer tank is integrated with the touch panel gas mixer [CUBEGM-X series]. The operability and functionality of the [CUBEGM-X series] has been taken over as it is, to cope with the supply flow fluctuation to the secondary side device.
Easy to move due to stoppered casters.
You can design and manufacture according to your application, specifications and budget. The capacity of the buffer tank can be suggested according to your request and specifications. In addition, since mixed gas (2 types) concentration meter can be installed, please feel free to contact us for more details.
- [CUBEGM-Xα Seires (Buffer tank specification)] is an all-in-one unit which have Touch panel, PLC unit, Mass Flow Controller, Power supply, Valve, Check Valve Gas Mixer and Buffer tank.
- Program operation: Program operation is possible by setting the flow rate and time of each line.
Specifications
Model | CUBEGM-X Series |
---|
Size | CUBEGM-Xα2 : W350×D400×H1100(mm) ※Except protrusion / In the case of 10 L tank
CUBEGM-Xα3 : W430×D400×H1100(mm) ※Except protrusion / In the case of 10 L tank
CUBEGM-Xα4 : W510×D400×H1100(mm) ※Except protrusion / In the case of 10 L tank |
Input power | AC100-240V |
Current consumption | About 125VA ※In the case of 3 mass flow controllers equipped with |
Flow rate control range | 1 LINE : F.S.10SCCM~20SLM (However, the mixed gas flow rate must be less than 50 SLM) |
Flow rate control | MFC : C1000 Series or FCST1000L Series |
Flow rate output signals | 0-5VDC |
INLET, OUTLET Valve | Solenoid Valve |
Leak Integrity | ≦5×10-7Pa・m3/sec He |
Pressure resistance | 0.5MPa |
Wetted surface material | SUS316, PTFE, Fluoro-Rubber
(FCST1000L Series : Magnetic stainless steel, Fluoro-Rubber or Chloroprene rubber) |
Standard fitting | 1/4in.SWL (equivalent) ※For other fitting, please contact us. |
Operating environment | 5-50℃, 30-80%RH (Scope of accuracy guarantee : 15-35℃) |
Accessory | AC cable(2m), User’s manual, Written guarantee |
● May be changed items depend on the number of mass flow controller. The other specifications, please contact us.