CS Instruments Dew Point Sensor FA 410 For Monitoring Membrane And Adsorption Dryers

Typical use in compressed air dryers / granulate dryers at very low dew points down to -80°Ctd

Description

Typical use in compressed air dryers / granulate dryers at very low dew points down to -80°Ctd.

Brand

CS Instruments

CS Instruments

CS Instruments GmbH & Co. KG with locations in 24955 Harrislee and 78052 Villingen-Schwenningen/ Tannheim, is managed by Dipl. Eng. (FH) Wolfgang Blessing as sole Managing Director.

CS Instruments GmbH was established in the year 2002 by Christian Schuldt and Wolfgang Blessing as equal shareholders/Managing Directors.

Wolfgang Blessing already was sound a specialist on the sector of compressed air technology resp. industrial measurement technology long before the establishment of CS Instruments GmbH in the year 2002. Prior to the foundation of CS Instruments GmbH Dipl. Ing. (FH) Wolfgang Blessing acted for more than 10 years as primarily responsible product manager for industrial measurement technology at a worldwide known manufacturer of measuring instruments for compressed air and gases in the Black Forest. The technical knowledge and experience matched with the long-term practical knowledge was the corner stone for the success of CS Instruments.

Features

  • Measuring range -80…20°Ctd
  • Extremely long-term stable
  • Analogue output 4…20 mA
  • Condensation insensitive
  • Quick response time
  • Pressure-tight up to 350 bar (special version)

Applications

  • Mounting with standard measuring chamber for
    compressed air up to 16 bar
  • Easy installation via quick couplin

Specifications

  • Measuring
    range:
    -80…20°Ctd resp.
    -20…50°Ctd
  • Accuracy: ± 1°C at 20…-20°Ctd
    ± 2°C at -20…-50°Ctd
    ± 3°C at -50…-80°Ctd
  • Pressure range: -1…50 bar
    special version up to
    350 bar
  • Power supply: 24 VDC (16…30
    VDC)
    Protection
    class: IP 65
  • EMV: according to DIN EN
    61326
  • Operating temp: -20…70 °C
  • Connection: M12, 5-pole
  • PC connection: SDI interface
  • Analogue output:
    4…20 mA =
    -80…20°Ctd resp.
    4…20 mA =
    -20…50°Ctd
  • Burden for analogue output: ȍ
  • Screw-in thread: G 1/2“
  • Dimensions: Ø 30 mm, length
    approx. 130 mm
  • Via servcie
    software:
    – choose units
    – scaling
    % RH, °Ctd, g/m³,
    mg/m³, ppm V/V
    change 4…20 mA
  • Special version: 4…20 mA, 2-wire
    technology

Additional Informations

  • Standard measuring chamber : for compressed air up to 16 bar
  • Control and calibration set for dew point sensors : is screwed onto the dew point sensor and therefore enables an easy and low-priced possibility for on-site control and calibration down to -20°Ctd.