Rheonik RHM100 Coriolis Mass Flow Meter is a high throughput Coriolis mass flow meter designed for plant balance and loading/unloading applications with trucks, railcars, barges, tankers and pipelines.
- Range: 120 kg/min up to 12000 kg/min
- Pressure: up to 208 bar (3016 psi)
- Temperature: -196°C (-321°F) up to +210°C (410°F)
- Accuracy: 0.1 % of rate
- Materials: SS 316L / SS 316Ti, Super Duplex – 1.4410, Alloy C22 – 2.4602
- Process Connection: 8″ up to 8″
Features
- Typical measuring range up to 12000 kg/min (26455.47 lb/min)
- Pressure ratings up to 237 bar (3437 psi)
- Temperature ratings from -196 to +210 °C (-320 to +410°F)
- Mass flow uncertainty down to 0.1 %
- Repeatability down to 0.05 %
- 4 kHz measurement updates and response time of less than 10 ms when used with RHE 40
Series transmitters - Accurately measure flow rates down to 150 kg/min
- The Rheonik AnyPipeFit Commitment provides custom process connection type and size
flexibility on any meter to suit your existing plant, saving time and expense on installation costs - Approved for use in hazardous areas
- SS 304 Stainless steel enclosure, SS 316 optional
- Integral and remote transmitter versions available
Read More : Prinsip Kerja, dan Aplikasi Laminar Flow Meter
Application
- Terminal Transfer / Viscous Fluids / Barge
- Ship
- Rail Car and Truck Filing
Read More : Cara Kerja, Aplikasi, dan Keuntungan Orifice Flow Meter
Benefits
- Torsion oscillator design assures a stable and drift-free measurement with excellent signal to noise ratios
- Resilient to external noise and vibration
- Insensitive to pipe pressure changes
- Robust tube wall thickness provides increased operational safety in abrasive applications
- Corrosion-resistant
- Long sensor life guaranteed due to low mechanical stresses in the meter mechanism
- No moving parts to wear or fail
Read More : Prinsip Kerja, Aplikasi, dan Kelebihan V-cone Flow Meter
General Specifications
Nominal Flow (Qₙₒₘ)* | 10000 kg/min (22046 lb/min) |
Maximum Flow (Qₘₐₓ)* | 12000 kg/min (26456 lb/min) |
Typical Minimum Flow (Qₘᵢₙ)* | 150 kg/min (330 lb/min) |
Operating Temperature | Fluid temperature range options cover applications from -196°C to 210°C (-320°F to 410°F). For integral transmitter versions please refer to transmitter datasheet |
Ambient Temperature | -50°C to 80°C (-58°F to 176°F) |
Pressure Ratings | Up to 237 bar / 3437 psi – dependent upon material |
Electrical Connection Sensor | M20 x 1.5 standard cable entry for JM, SM terminal box versions Optional entries available : ½” NPT or M25 x 1.5 (only for SM) or ¾” NPT (only for SM) Max. cable length to remote RHE transmitter 100 m / 328 ft |
Sensor Enclosure Materials | Stainless steel 304 (standard), SS 316 (optional) Coated aluminum terminal box, SS 316 terminal box (optional) |
Enclosure Type | Protection class IP65, NEMA 4 (standard); IP66 / NEMA 4X (optional) |
Wetted Materials | 1.4571 (SS 316Ti), 1.4410 (SuperDuplex) – standard 2.4602 (Alloy C22) – consult Factory Additional/customer specific materials available upon request |
Process Connections | Nearly any – the Rheonik AnyPipeFit Commitment. Consult factory for types/sizes not listed in this data sheet on the Mechanical Construction pages |
Pressure Rating Compliance | Europe – PED: Module B3.1+C2 Canada – CRN: Canadian Registration Number |
Certifications and Approvals | ATEX / IECEx Approvals for Zone 0, 1 (details see page 11) North American Approvals Class I, Div. 1, 2, Gr. A,B,C,D, Zone 0, 1, 2 MID custody transfer approval (OIML R117) American Bureau of Shipping (ABS) Product Type Approval for use on marine vessels |
Testing and Inspection | All sensors are hydro tested, calibrated and supplied with a traceable calibration certificate. Customized calibration and testing services are available |
Project Documentation and QA, Services | Rheonik offers a full set of services for large and complex engineering projects. •Certificates of origin and conformity, mill certificates •Data books including WPAR, WQS, NDT, test & quality plans, functional testing, calibration procedures, customized packing, factory acceptance etc. •Painting to project specification •Start up and commissioning services on/offshore |
Options | Enclosure heating for high temperature applications Cleaning for oxygen service , … For more consult factory |
Read More : Prinsip Kerja Optical Flow Meter
Performance Data
- Flow Measurement Uncertainty
- Selected Sensors down to ±0.10 % ¹ of rate (Gold Line)
- Standard Sensors down to ±0.15 % ² of rate
- Flow Measurement Repeatability
- Down to ±0.05 % of rate
- Temperature Measurement
- Better than ±1 °C
- Density Calibration (Liquid)
- Selected Sensors down to ±0.0005 kg/liter (Gold Line)
- Standard Sensors down to ±0.001 kg/liter
Common Dimensions for all Construction Types
Standard blue aluminum terminal box, size = 125 x 80 x 57 mm (4.92 x 3.15 x 2.24 in)
Terminal boxes are supplied with an M20 x 1.5 cable entry and a polyamide compression cable gland fitting (for cable diameters 7 – 14 mm / 0.28 – 0.56 in). M25 x 1.5, 1⁄2” NPT, 3⁄4” NPT cable entries (without gland) are optionally available and must be ordered separately
Optionally available: SS 316 box, size = 100 x 100 x 61 mm (3.94 x 3.94 x 2.40 in) – only with remote transmitter