Hengesbach PZM 100/101 Flush-Mounted Pressure and Level Transmitter

Flush-Mounted Pressure and Level Transmitter Hengesbach PZM 100101

Table of Contents

Informasi Hengesbach PZM 100/101 Flush-Mounted Pressure and Level Transmitter

Hengesbach PZM 100/101 Flush-Mounted Pressure and Level Transmitter cocok untuk melakukan pengukuran tekanan dan tingkat pengisian di saluran pipa dan wadah. Sistem koneksi proses modular menawarkan berbagai adaptor koneksi dan membantu memangkas biaya dalam jangka panjang.

Sambungan proses yang dipasang rata dengan seal O-ring dan membran baja tahan karat disertifikasi untuk EHEDG tipe EL-ASEPTIC CLASS 1 dan dengan demikian ditentukan sebelumnya untuk pengukuran yang memenuhi persyaratan kebersihan yang paling ketat sekalipun.

Hengesbach PZM 100101 Flush-Mounted Pressure and Level Transmitter
Hengesbach PZM 100101 Flush-Mounted Pressure and Level Transmitter

Rentang pengukuran sensor dari sel pengukur tahan vakum piezoresistif dengan membran baja tahan karat dari pemancar tekanan Hengesbach PZM berkisar dari -1/0…0,35bar hingga -1/0…100bar.

Rentang pengukuran khusus dimungkinkan untuk kedua versi. Semua pemancar tekanan dalam seri 100/101 dirancang untuk aplikasi universal dan, khususnya, untuk aplikasi dengan suhu tinggi terus-menerus hingga 200°C. Selain itu, dengan menggunakan tampilan di tempat dengan seri 100 dan modul tampilan dan pengoperasian OPUS M dalam seri 101, pemancar tekanan dapat dengan mudah dibaca, dikonfigurasi, dan didiagnosis.

Baca Selengkapnya : Delta Mobrey Magnetic Vertical Level Switches

Fitur Hengesbach PZM 

  • Sistem koneksi proses modular bersertifikasi EHEDG-aseptik
  • pengukuran presisi ≤ ± 0,15% FS
  • Matikan 10
  • layar terintegrasi atau eksternal dan modul operasi OPUSM
  • bukti vakum dan sangat aman
  • entri langsung dari parameter dengan tampilan teks biasa
  • mudah dibersihkan dan kelas perlindungan tinggi IP 67 dan IP69K
  • kekuatan aplikasi: pengukuran tekanan konten dan proses / pengukuran vakum bahkan pada suhu tinggi

Baca Selengkapnya : Aplisens ERH Level Switch

Spesifikasi Hengesbach PZM 

General details
Device type / measuring principlePZM 100/101: piezoresistive
VRM 100/101: capacitive
Input
Measuring rangesPZM 100/101VRM 100/101
Standard nominal measuring range [bar]relativeOPabsoluteOPrelativeOPabsoluteOP
OP = overload protection [bar]0…0.3510…425
0…130…13-1/0…4250…1040
-1/0…2.580…2.58-1/0…10400…2040
Special measuring ranges are available on request.-1/0…5150…515-1/0…20400…4060
-1/0…10300…1030-1/0…40600…70105
-1/0…30900…3090-1/0…70105
-1/0…1002500…100250
Setting the measuring rangesVia the keypad of the OPUSM display and operating module / via the integrated on-site display
Setting rangesStart the measuring zero:0…90% of the sensor’s nominal measuring spanTD=10
Measuring span:10…100% of the sensor’s nominal measuring span
Burst pressure DIN16086≥ 4-fold measuring range
Output
Output signal2-wire:   4…20mA with a test circuit connection in the device
Fault signalOptional: 3.8mA, 22mA, hold (i.e. holding the last value)
Current limitation3.85mA and 21.5mA (normal operation)
Integration timeContinuously selectable between 0 and 300s (setting time after a pressure leap)
Measuring accuracy
Reference conditionsacc. to DIN IEC 770
Linearity, hysteresis and repeatability as per the limit point method DIN IEC 770≤ ± 0.15% of the sensor’s nominal measuring range
DIN IEC 770
Activation time< 5s (the device will carry out a self-test.)
Setting time (without damping)< 200ms
Long-time drift≤ 0.2% of the span per year
Thermal hysteresis≤ ± 0.75% beginning of the measuring range / ≤ ± 0.8% end of the measuring range (VRM)
≤ ± 0.2% of the sensor’s nominal measuring range / 10K (-20…+80°C) from 4 bar (PZM)
≤ ± 0.3% of the sensor’s nominal measuring range / 10K (-20…+80°C) up to 0.6 bar (PZM)
Conditions of use
Installation position / calibration positionAny position / standing vertically
Medium temperaturePZM:T1:-40…+125°C (140°C over one hour at the most)
T2:-40…+200°C (high-temperature version)
VRM:-40…+140°C
Ambient storage temperatureType 101:-40…+85°C
Type 100:-30…+75°C
(Below -20°C cable breakage might occur and the display’s function may be impaired.)
Protection class acc. to EN60529IP 67 and IP 69K
Electromagnetic compatibilitySensitivity against interference: acc. to DIN IEC 61000-6-2
Interference radiation:acc. to DIN IEC 61000-6-4
Construction
Electrical connection– Standard: cable screw connection M16x1.5, nickel-plated brass, stainless steel available on request
– Optional: round plug-in connector M12x1, nickel-plated brass, stainless steel available on request
– Optional: angle plug acc. to EN 175301-803
– Optional: reference cable
Process connection– Membrane, flush-welded on the front, CrNiSt, other materials available on request
– EHEDG type EL-ASEPTIC CLASS 1, certified connection system PZM / VRM
with press screw M38x1.5 and elastomer sealing
– Process seal EPM (FDA) (temperature range: -20…+150°C)
– Process seal FPM (FDA) (temperature range: -40…+200°C)
Materials– Field housing / lid:CrNiSt 1.4301 (304)
– Housing seal:FPM (Viton®)
– Pressure compensation element:polyamide
– Inspection gauge (type 100):polycarbonate
– Process connection/connection adapter:CrNiSt 1.4404 (316L)
– Process membrane:CrNiSt 1.4435/1.4404 (316L)
– Locking screw (type 101):CrNiSt 1.4301 (304)
– Reference cable: 5-wire with reference tube:  PUR (recommended: 80m maximum)
Filling fluidPZM:silicon oil (FDA)
VRM:medical mineral oil (FDA)
Display and operation
DisplayLCD, 4-digit numerical display, and 5-digit alphanumerical display
Type 100:integrated on-site display (cannot be separated from the device)
Type 101:external OPUSM display and operating module
Displayable unitsPressure:mbar, bar, psi, Pa, mH2O, mmHg, Torr, atm, at, kg/cm²
Temperature*1:°C, °F, K, °R, °Ré
Additional displaysOutput current in mA or % (in relation to the span)
Operation100.00.00via the configuration menu with the integrated on-site display
101.00.00via the configuration menu with the external OPUSM display and operating module
Auxiliary energy resources
Power supply/burden12-36V DC, max. burden: (V supply – 12V) / 24mA
Accessories 100 series
OPUSM display and operating moduleExternal display and operating module, CrNiSt, IP 67, 41x70mm, 1m connection cable and round plug-in connector M12x1
CertificatesCalibration certificate
Declaration of conformity
Material inspection certificates as per EN 10204
EHEDG certificate

Baca Selengkapnya : Bamo Ultrasonic Level Transmitter for Liquids BAMOSONIC