Accuracy | : ≤1% |
Velocity Range | : 0~±10m/s, Bi-directional measurement |
Pipe Size | : DN15~DN2000mm |
Temperature | : -30°C~160°C |
Type of Liquid | : water, sea water, sewage, oil, alcohol, etc. |
Pipe Material | : Steel, stainless steel, cast iron, copper, PVC, Aluminum, glass steel, etc. inside Linning is allowed. |
Signal Output | 1 way 4-20mA output1 way OCT pulse output 1-way Relay output |
Signal input | : 3 way 4-20mA input, achieve to heat measurement by connecting PT100 platinum resistor. |
Interface | : RS485, support MODBUS |
Data Storage | : SD card regularly store the pre-set result(optional) |
Power Supply | : DC8~36V or AC85~264V |
Untuk posisi installasi transite time clamp on ultrasonic flow meter ini juga menganut aturan instalasi sebagaimana velocity flow meter, dimana diusahakan pada posisi pemasangan transducer, isi dari cairan dalam pipa harus penuh dan alirannya sedapat mungkin laminer. S
edangkan aturan jarak pemasangan sensor ultrasonic juga memerlukan jarak tertentu terhadap up stream dan down stream.
Berikut ini jarak pemasangan transducer flow meter ultrasonic :
Flowmasonic WUF 100CF dapat menampilkan data aliran berupa Kecepatan aliran atau velocity dengan satuan units jarak perwaktu, debit aliran atau flow rate dengan satuan unit volume per waktu dan totaliser yang merupakan volume dari cairan ang telah mengalir dlam waktu tertentu dengan satuan unit volumetric.ow rate aliran dalam kanal.
Sumber : inaparts.com
Baca Juga :
Page: 1 2