| Pipe Sizes | | 2″, 3″, 4″, 6″, 8″, 10″, 12″ |
| Flanges | | 150 lb. ANSI Pattern |
| Pressure | | 150 psi (10.3 bar) line pressure |
| Temperature | Operating | 10° to 140° F (-12° to 60° C) |
| Humidity | Humidity 0-90% RH to 60° C, altitude 2000m |
| Storage | -40° to 158° F (-40° to 70° C) |
| Accuracy | | $pm$0.75% of reading on iMAG 4700p and 4700r ($pm$1.0% iMAG 4700), $pm$0.025% of full-scale flow from low flow cutoff to maxi. flow rate of 10 m/sec |
| Low Flow Cutoff | | 0.5% of maximum flow rate |
| Material | Body | Welded steel, epoxy-coated |
| Liner | Polyurethane/Noryl® |
| Electronics Housing | Powder-coated diecast aluminum |
| Electrodes | 316 stainless steel standard/ Hastelloy optional |
| Display | Type | 128×64 dot-matrix LCD |
| Digits | 5 Digit Rate; 8 Digit Total |
| Units | Rate Volume Units: Gallons, Liters, Barrels, Cubic Feet, Cubic Meters, Million Gallons, Mega Liters, Imperial Gallons, Million Imperial Gallons |
| | Rate Time Units: Second, Minute, Hour, Day |
| | Total Volume Units: Gallons, Liters, Kilo Liters, Mega Liters, Barrels, Cubic Meters, Cubic Feet, Second Foot Day, Million Cubic Feet, Acre Feet, Acre Inches, Imperial Gallons, Fluid Ounces |
| Bidirectional | Forward Total, Reverse Total, Net Total, Batch Forward Total, Batch Reverse Total |
| Power | DC Power | 9-36 Vdc @ 250 mA max |
| Battery Backup | DC units: One lithium 7.2V ‘D’ size battery pack; AC units: One 9V alkaline battery |
| AC Power | 100-240Vac, 50/60Hz, 0.12A (iMAG 4700r and 4700p only) |
| Battery | One lithium 7.2V ‘D’ size battery pack (iMAG 4700 only) |
| Scaled Pulse Output | Signal | Current sinking pulse, isolated, 36 Vdc at 10 mA max |
| Pulse Rates | User-scalable from 0.1 to 99,999.9 volume units/pulse |
| Options | 4-20mA Current Loop | Isolated, passive, 24Vdc, 650 $Omega$ maximum current loop |
| High Speed Digital | Isolated, open collector, 24 Vdc (iMAG 4700p only) |
| Serial Communications | Isolated, asynchronous serial RS485, Modbus® RTU protocol |
| Cable | Power/Output Cable | 20ft (6m) standard length polyurethane jacketed cable |
| Remote Display Cable | 20ft (6m) standard length (iMAG 4700r) |
| Conductivity | | >20 microSiemens/cm |
| Empty Pipe Detection | | Hardware/software, conductivity-based |
| Regulatory | | CE, NSF/ANSI standard 61, CSA/CUS |
| Environmental | | NEMA 6P, CSA 6P, IEC 60925 IP68 (10ft/3m depth, continuously) |