Wenglor P1KE001 Through Beam Sensor

The through-beam sensor works with red light as well as a transmitter and a receiver. Thanks to their high light intensity, the sensor provides a high degree of operational reliability even with interferences like steam, fog or dust. The transmitter can be deactivated using test input in order to test the functionality of the through-beam sensor. The IO-Link interface can be used to configure the sensor (PNP/NPN, NC/NO, switching distance), as well as for reading out switching statuses and signal values.

Description

The through-beam sensor works with red light as well as a transmitter and a receiver. Thanks to their high light intensity, the sensor provides a high degree of operational reliability even with interferences like steam, fog or dust. The transmitter can be deactivated using test input in order to test the functionality of the through-beam sensor. The IO-Link interface can be used to configure the sensor (PNP/NPN, NC/NO, switching distance), as well as for reading out switching statuses and signal values.

Brand

Wenglor

Wenglor

Technology that moves in over three decades of wenglor sensoric. On this interactive journey through time, we researched deep into wenglor’s archives and have tracked the history of the company since the eighties – starting in an attic and growing into a global corporation.

The innovative company for smart sensor and image processing technologies. Many patented product and system solutions are used in countless automated industries worldwide. Constant growth, outstanding products and excellent corporate governance qualify wenglor as a top employer in the SME sector.

Features

  • Condition monitoring
  • High light intensity with large switching reserve
  • IO-Link 1.1
  • Test input for high operational reliability

Applications

05 = Switching Distance Adjuster
30 = Switching Status/Contamination Warning
68 = supply voltage indicator

Specifications

Optical Data

Range6,000 mm
Smallest Recognizable Partsee Table 1
Switching Hysteresis < 10 %
Light SourceRed Light
Service Life (T = +25 °C)100,000 h
Max. Ambient Light10,000 Lux

Electrical Data

Sensor TypeReceiver
Supply Voltage10 … 30 V DC
Supply Voltage with IO-Link18 … 30 V DC
Current Consumption (Ub = 24 V)< 20 mA
Switching Frequency1,000 Hz
Switching Frequency (interference-free mode)500 Hz
Response Time0.5 ms
Response time (interference-free mode)1 ms
Temperature Drift< 10 %
Temperature Range-40 … 60 °C
Switching Output Voltage Drop< 2 V
Switching Output/Switching Current100 mA
Residual Current Switching Output< 50 µA
Short Circuit and Overload Protectionyes
Reverse Polarity Protectionyes
Lockableyes
InterfaceIO-Link V1.1
Protection ClassIII

Mechanical Data

Setting MethodPotentiometer
Housing MaterialPlastic
Degree of ProtectionIP67/IP68
ConnectionCable, 3-wire, 2 m
Optic CoverPMMA

Safety-relevant Data

MTTFd (EN ISO 13849-1)2,111.25 a

Output

PNP NOyes
IO-Linkyes

Adjustable parameters

OutputPush-pull
NPN
PNP
CircuitNC
NC/NO
NO
Other parametersOff-delay
On-delay
Mode of operation
Hysteresis
Switching point

Table 1

Distance transmitter/receiver1 m2 m6 m
Smallest Recognizable Part4 mm1 mm1 mm

Couldn’t find what you were looking for?

Contact us with your specification for assessment and availability of other products configurations.

Click Here