Wenglor OEWK803A0002 Through Beam Sensor

These through-beam sensors are best suited for use in industrial environments. Thanks to their large working range, the devices demonstrate excellent functional reliability in highly contaminated environments. The sensors can be checked for correct functioning via the test input.

Description

These through-beam sensors are best suited for use in industrial environments. Thanks to their large working range, the devices demonstrate excellent functional reliability in highly contaminated environments. The sensors can be checked for correct functioning via the test input.

Brand

Wenglor

Wenglor

Technology that moves in over three decades of wenglor sensoric. On this interactive journey through time, we researched deep into wenglor’s archives and have tracked the history of the company since the eighties – starting in an attic and growing into a global corporation.

The innovative company for smart sensor and image processing technologies. Many patented product and system solutions are used in countless automated industries worldwide. Constant growth, outstanding products and excellent corporate governance qualify wenglor as a top employer in the SME sector.

Features

  • Switching distance adjuster
  • Clever inclusive mounting technology
  • Simple installation
  • Large working range
  • Minimal installation space

Applications

05 = Switching Distance Adjuster
68 = supply voltage indicator
01 = Switching Status Indicator

Specifications

Optical Data

Range8,000 mm
Switching Hysteresis < 15 %
Light SourceRed Light
Service Life (T = +25 °C)100,000 h
Max. Ambient Light10,000 Lux
Opening Angle4 °

Electrical Data

Sensor TypeReceiver
Supply Voltage10 … 30 V DC
Current Consumption (Ub = 24 V)< 20 mA
Switching Frequency600 Hz
Response Time833 µs
Temperature Drift< 10 %
Temperature Range-25 … 60 °C
Switching Output Voltage Drop< 2.5 V
PNP Switching Output/Switching Current100 mA
Residual Current Switching Output< 50 µA
Short Circuit and Overload Protectionyes
Reverse Polarity Protectionyes
Protection ClassIII

Mechanical Data

Setting MethodPotentiometer
Housing MaterialPlastic
Degree of ProtectionIP67
ConnectionM12 × 1; 4-pin

General Data

Scope of deliveryMounting Console

Output

PNP NO/NC antivalentyes

Adjustable parameters

CircuitNC
NC+NO
NO