Description
The HD1200 advanced level sensing algorithm suppresses the noise level and artifacts and enabled stable measurement.One main unit handles two sensors at once. Two different types of sensors can be installed and each may measure different ranges.
Data logging function to micro SD TM. Flow measurement by measuring the catchment level is possible.
Specification
Model No. | HD1200 |
---|
Channel | 2 |
Frequency | 10 to 60 kHz (select by sensor) |
Measurement object | liquid / powder |
Resolution | Measurement | 1 mm |
display | 1 mm |
Accuracy | ±0.25% F.S. |
Data refresh rate | 2 sec. approx. (depends on sensor) |
Power source | Voltage | 100 to 240 V AC ±10 % |
Power consumption | 10 VA |
Display | LCD with backlight |
Output | Alarm | 4 points / channel
250VAC, 5 A (relay contact) |
4-20mA current | Resolution: 1/4000
(Max. load resistance 600Ω) |
Interface | RS-485 (max. distance: 1200 m or less)
RS-232C (max. distance: 10 m or less) |
Memory | microSDTM *1 |
Operation temperature | -20 to 70℃ |
Material | ABS |
Protection | IP66 equivalent |
Dimension (WxDxH mm) | 176x84x237 |
Weight | 1.8 kg |
NOTE : Weir type flowmeter is available on CH1
*1 : microSDTM is a trademark of SD Card Association
Model No. | Sensor |
---|
TS40-5 | TS40T-5 |
Frequency | 40 kHz |
Measurement range
(1/2 value for powder) | 0.3 to 20m | 0.3 to 15m |
Directive angle
(half of full angle) | 12°(-6dB)
8°(-3dB) | 22°(-6dB)
16°(-3dB) |
Operation temperature | -20 to 70℃ |
Material | Epoxy/silicone/ PP | PVDF |
Protection | IP68 equivalent | IP68 equivalent |
Dimension (mm) | dia. 84×90 | dia. 98×87 |
Sensor cable length | 5m |
Weight | 500g | 860g |
Mounting screw | R1 (PT1) | G1 (PF1) |
●TS40T-5 is chemical resistant.
●The sensors cannot be used in hydrofluoric acid environment.