Spesifikasi Flowmasonic WUF 100CF

Berikut spesifikasi Clamp on ultrasonic flow meter model WUF-100CF

Accuracy : ≤1%
Velocity  Range : 0~±10m/s, Bi-directional measurement
Pipe Size : DN15~DN2000mm
Temperature : -30°C~160°C
Type of Liquid : water, sea water, sewage, oil, alcohol, etc.
Pipe Material : Steel, stainless steel, cast iron, copper, PVC, Aluminum, glass steel, etc. inside Linning is allowed.
Signal Output 1 way 4-20mA output1 way OCT pulse output

1-way Relay output

Signal input :  3 way 4-20mA input, achieve to heat measurement by connecting PT100 platinum resistor.
Interface : RS485, support MODBUS
Data Storage : SD card regularly store the pre-set result(optional)
Power Supply : DC8~36V or AC85~264V

Installasi

Untuk posisi installasi transite time clamp on ultrasonic flow meter ini juga menganut aturan instalasi sebagaimana velocity flow meter, dimana diusahakan pada posisi pemasangan transducer, isi dari cairan dalam pipa harus penuh dan alirannya sedapat mungkin laminer. S

edangkan aturan jarak pemasangan sensor ultrasonic juga memerlukan jarak tertentu terhadap up stream dan down stream.

Berikut ini jarak pemasangan transducer flow meter ultrasonic :

3dd33-installationsiteselection

Flowmasonic WUF 100CF dapat menampilkan data aliran berupa Kecepatan aliran atau velocity dengan satuan units jarak perwaktu, debit aliran atau flow rate dengan satuan unit volume per waktu dan totaliser yang merupakan volume  dari cairan ang telah mengalir dlam waktu tertentu dengan satuan unit volumetric.ow rate aliran dalam kanal.

Sumber : inaparts.com